Axio Imager
CYTOGENETIC WORKSTATION ON UPRIGHT RESEARCH MICROSCOPE
UPRIGHT RESEARCH FLUORESCENCE MICROSCOPE
Axio Imager.A2″ microscope stand
– Z-drive man., with fine drive knob and fine drive disk, flat with scala, changeable
– stage/condenser carrier, detachable
– transmitted-light illumination man.
– double filter wheel, discrete, man.
with neutral-density filter set
– Light Control man. with RS 232 interface
– integrated 12V DC 100W power unit, stabilized,
100V…240V AC/50…60Hz/168VA
– country-specific line cable and RS 232 cable
7-position objective nosepiece, HD M27 cod.
Filter set transm. light with neutral-density and color filters, d=25 consisting of 4 neutral-density filters 1x 25%, 2x 6% and 1x 1.5% transmission, as well as 1x green filter and 1x conversion filter 3200-5500K.
Binocular phototube 15°/25 (100:0/0:100), upright image adjustable stop, camera port with interface 60N
Dust protection Set L
Camera Adapter 60N-C 1″ 1.0x
Mechanical stage 75×50 R with hardcoat anodized surface
Specimen holder 76×26, one-hand operation for immersion
HAL 100 illuminator with quartz collector
Bulb 12V 100W Halogen Rectangular Filament
Objective “A-Plan” 10x/0.25 M27
Objective “A-Plan” 40x/0.65 M27
Objective EC “Plan-Neofluar” 100x/1.30 Oil M27
Eyepiece PL 10x/23 Br. foc.
Eyepiece eyecup
Achromatic-aplanatic pathology condenser 0.9 H
Epi-fluorescence Attachment
Reflected-light illuminator for FL and HD for “Axio Imager” with shutter
Stop slider with centerable luminous-field diaphragm, slider stop position can be set
6-position reflector turret man. cod. for P&C moduless
Reflector module FL EC P&C
Filter set 49 DAPI shift free
EX G 365, BS FT 395, EM BP 445/50
Filter set 10 shift free FITC
EX BP 450-490, BS FT 510, EM BP 515-565
Filter set 15 shift free TRITC
EX BP 546/12, BS FT 580, EM LP 590
HBO Illumination
HBO 50 illuminator with collector
Burner Mercury – HBO 50 AC L1 (F)
Power supply unit for HBO 50
CYTOGENETICS WORKSTATION
CoolCube 1 High Resolution Digital monochrome version USB Camera
RESOLUTION: 1360 x 1024 pixels (SXGA)
SENSOR: 2/3”, quadratic pixels, EXview HAD CCDTM monochrome (CoolCube 1m) 2/3”, quadratic pixels, EXview HAD CCDTM color (CoolCube 1c)
FULL WELL CAPACITY: 17,000 e
FRAME RATE: 15 fps @ full resolution
SHUTTER: Global Shutter,
EXPOSURE TIME: 80 µs to 270 s
PIXEL SIZE: 6,45 µm x 6,45 µm
DIGITIZATION DEPTH: 12 Bit, GAIN 1 – 16
DATA INTERFACE: High-Speed USB2.0
INTERNAL IMAGE MEMORY: 32 MByte
POWER SUPPLY: USB Bus Powered
POWER CONSUMPTION: 2.4 W
MECHANICAL INTERFACE: C-Mount
DIMENSIONS: 70 mm x 70 mm x 70 mm, WEIGHT: 730 g
FISH Imaging Software
Isis software licence complete
Software package for imaging and processing of fluorescence images.
Functionality includes:
• Image acquisition in up to 9 color channels with integrated microscope control for motorized microscopes
• Interactive and automatic integration time control for each color channel
• Live image display on the computer monitor
• Automatic and interactive background correction and thresholding for each color channel
• Interactive and automatic color registration
• Contrast optimization for region of interest and entire image
• Mask (exclude/include) function , Transient and permanent zoom
• Presentation of individual colors, false colors, and gray levels
• Focus stack option , Annotation capabilities, Measurement functions
• Image management and retrieval by image galleries
• Numerous print options
• Image export into other applications in TIF, JPG, and BMP-format
• Integrated patient/case database with search functions
• Modular upgrades
UPRIGHT FLUORESCENCE RESEARCH MICROSCOPE WITH FISH IMAGING SOFTWARE COMPLETE AS ABOVE, F.C.A GERMANY
CE Certified