- Liquid Chromatography
- Pharmaceutical Physical Testing
- Life Science
- Analytical & Enterprise Solutions
- Laboratory Equipment
- Freezer
- Refrigerator
- Centrifuge
- Shaker
- Incubator
- Oven
- Muffle Furnace
- Water Bath
- Water Purification
- Sterilizer
- Laminar Airflow
- Biosafety Cabinet
- Desiccator
- Data Logger
- Plant Growth Chamber
- Stirrer Line
- Micropipette
- Measuring Viscosity
- Rotary Evaporator/Separation
- Bomb Calorimeter
- Temperature Controlling System
- Mill
- Chiller
- Electrochemistry
- Heating System
- Crushing/Disperser
- Laboratory Filtration & Separation Technologies
- Water & Environment
- TOC Analyzers
- Microscopy
- Food & Feed Line
- Balance
- Flow Cytometry
- LC-MS/LC-MS-MS
- LC Software
- Gas Generators
- Waters Corporation, USA
- Pharma Test Apparatebau AG, Germany
- BioMerieux S.A, France
- Perkin Elmer, USA
- HACH Company, USA
- Carl Zeiss Microscopy GmbH, Germany
- Thermo Fisher Scientific, USA
- Cytiva (Whatman), USA
- Veolia Water Technology & Solutions, France
- VELP Scientifica srl, Italy
- IKA, Germany
- NUVE, Turkey
- Himedia Laboratories Pvt. Ltd., India
- IDEXX Laboratories, USA
- Sartorius, Germany

Model: DRB 200(single) with digestion vial
DRB 200 Dry Thermostat Reactor provides unique one-key operation. Programs for Hach procedures with digestion are preprogrammed into the instrument. And it’s fast—the block heats from 20 to 150°C in less than 10 minutes. Have both single & double block max up to 42 sample position depending on hole dia: 13, 16 & 20 mm.
Technical Data
- Programmable Temperature Range: 37 to 165°C (99 to 329°F)
- Programmable Timer Range: 0 to 480 minutes
- Heating Rate: 20 to 150°C in 10 minutes
- Temperature Stability: ± 1°C
Stored Programs
- COD: 150°C 120 minutes
- TOC: 105°C 120 minutes
- Fixed: 100, 105, 30, 60, 150, 165°C 120 minutes
- Single block: 9 16-mm and 2 20-mm or 15 16-mm

Model: BODTrak™II
BODTrak II Apparatus measures BOD using the respirometric method.
Features:
- Capacity: Six 492 mL bottles
- Range: 0 to 700 mg/L
- Selectable: 0 to 35, 0 to 70, 0 to 350, or 0 to 700 mg/L BOD (Biochemical Oxygen Demand)

Model: HRI3P-2 (220V)
HRI3P-2 B.O.D. incubator is thermoelectric cooled, eliminating the need for a refrigeration compressor. The incubators include a mechanical convection system to ensure even air distribution, digital temperature set controller, over temperature limit control, and a temperature display.
Features:
- Accuracy: ± 0.5 °C at 20 °C Temperature Uniformity
- Capacity: 90 B.O.D Bottles
- Dimensions Metric (H x W X D): 978 mm x 470 mm x 508 mm
- Temperature Range: 15 to 45 °C

Model: HQ40d BOD Measurement Package with LBOD101 Probe
(100/case), acrylic stoppers (25) and BOD bottle caps (1 packages of 6), 4 AA batteries, power adapter, USB/AC power adapter for data transfer, quick-start guide, user manual, and documentation CD.
Specification:
- Barometric Pressure Measurement: For automatic compensation of DO when using an LDO or LBOD probe
- BOD5/CBOD resolution: Available when used with Hach WIMS BOD Manager Software
- Cable resistance correction: Digital – not needed
- Calibration Curves Display: Calibration summary data logged and displayed
- Calibration Intervals/Alerts/Reminder: 2 hours to 7 days
- Custom Calibration Standards: User-defined standard sets
- Data Export: Download via USB connection to PC or flash memory device. Automatically transfer entire data log or as readings are taken.
- Data Memory: 500 results
- Data Storage: GLP/ISO compliant reading data stored with calibration details.
- Calibration details and check standard readings documented in data log.
- Automatically store in “press to read” mode and interval measurement mode.
- Manually store in “continous read” mode.
With Hach BOD Manager™ software automates data entry and calculations from the HQ40d Meter and LBOD optical dissolved oxygen probe, providing improved productivity and data integrity for Biochemical Oxygen Demand testing.